METHOD FOR PREDICTING PARAMETERS OF THE AEROIONIC MODE IN OPEN TERRAIN GROUND AREAS
DOI:
https://doi.org/10.15802/stp2019/170273Keywords:
ionization of air, sources of ion emission, numerical method, industrial site, concentration of aeroionsAbstract
Purpose. The scientific work is devoted to the development of a new method for forecasting aeroionic mode in working areas at industrial sites, taking into account ionizing sources and surrounding obstacles. Methodology. To find the concentration of positive aeroions, dust and negative aeroions, we use 3D mass transfer equations that take into account the rate of recombination of ions having different polarity and the rate of recombination of ions with dust particles. The numerical solution is based on the integration of the mass transfer equations using the finite-difference method, which turns out to be stable for any step in time. To determine the components of the air velocity vector, a three-dimensional model of the potential flow is used, where the Laplace equations for the velocity potential are the modeling equations. Findings. The mathematical method of numerical calculation of the concentration of positive, negative aeroions and dust has been developed. A feature of the method is the possibility of predicting the aeroionic mode, taking into account all physical factors that significantly affect the formation of concentration zones of aeroions in working areas at industrial sites. The method is not tied to a particular industrial site, it allows us to estimate the value of the concentration of aeroions both locally and in the entire calculated region. Originality. A method for prediction of aeroionic mode in working areas is developed based on 3D modeling of the propagation of negative, positive aeroions and dust under the influence of wind and diffusion, which allows to obtain results at each point of space or in a specific cross-section. Practical value. The proposed method of forecasting was used to solve the problem of estimating aeroionic mode in industrial zones in the open area of the industrial site of the Dnipro oil extraction plant in the presence of emission sources: positive aeroions during the operation of vehicles and respiration of workers; dust during the movement of workers and vehicles; negative aeroions of the ionizer installed in the working zone. The regularities of changes in the concentration of aeroions of various polarity and dust at a height of 1.7 m are determined, which corresponds to the position of the respiratory organs of workers. Quantitative results are needed in assessing the permissible working conditions in the workplaces of industrial sites of enterprises when creating new jobs and reengineering existing ones.
References
Belikov, A. S., Ragimov, S. Y., & Akinshin, V. D. (2010). Some aspects of the optimization of the study of working conditions on the microclimate in the industrial industry. Construction, material science, mechanical engineering, 52, 3-9. (in Russian)
Biliaiev, M. M., & Tsygankova, S. G. (2016). Modeling of the aeroionic mode in working zones in the conditions of artificial ionization of air. Science and Transport Progress, 1(61), 39-47. doi: http://doi.org/10.15802/stp2016/60947 (in Russian)
Vodianyk, A. O., & Vidnichuk, T. V. (2013). Metody vyznachennia kontsentratsii aeroioniv ta vmistu pylu u povitri vyrobnychykh prymishchen. Mistobuduvannia ta terytorialne planuvannia, 50, 77-81. (in Ukrainian)
Hlyva, V. A. (2011). Doslidzhennia vplyvu mikroklimatychnykh parametriv povitroobminu na aeroionnyi sklad povitria robochykh prymishchen. Problemy okhorony pratsi v Ukraini, 20, 58-65. (in Ukrainian)
Zaporozhets, O. I., Hlyva, V. A., & Sidorov, O. V. (2011). The Principles of Modeling of Dynamics of Ionic Composition of Indoor Air. Proceedings of the National Aviation University, 47(2), 120-124. doi: http://dx.doi.org/10.18372/2306-1472.47.24 (in Ukrainian)
Strokan, O. V. (2014). Prohramno-informatsiina systema optymizatsii mikroklimatu u vyrobnychomu prymishchenni. Bulletin of the National Technical University «KhPI». Series: New solutions in modern tech-nologies, 48(1090), 91-96. (in Ukrainian)
Tolkunov, I.O. (2015). Study Ways to Improve the Air Ion Mode in the Work Environment Facilities for Special Purposes. Science and technology of the air force of Ukraine, 1(18), 197-201. (in Ukrainian)
Chernyy, K. A. (2012). Metodologicheskiy podkhod k primeneniyu koronnykh aeroionizatorov pri provedenii korrektsii aeroionnogo sostava vozdukha pomeshcheniy. Magazine of Civil Engineering, 6(32), 48-53. (in Russian)
Chernyy, K. A. (2011). The up-to-date knowledge on the air ions nature and their classification. Bezopasnost’ Zhiznedeatel’nosti, 7(127), 15-20. (in Russian)
Zgurovskiy, M. Z., Skopetskiy, V. V., Khrushch, V. K., & Belyaev, N. N. (1997). Chislennoe modelirovanie rasprostraneniya zagryazneniya v okruzhayushchey srede. Kуiv: Naukova dumka. (in Russian)
Biliaiev, M. M., & Tsygankova, S. G. (2016). Complex of numerical models for computation of air ion concentration in premises. Science and Transport Progress, 2(62), 16-24. doi: http://dx.doi.org/10.15802/stp2016/67281 (in English)
Pushpawela, B., Jayaratne, R., Nguy, A., & Morawska, L. (2017). Efficiency of ionizers in removing airborne particles in indoor environments. Journal of Electrostatics, 90, 79-84. doi: http://dx.doi.org/10.1016/j.elstat.2017.10.002 (in English)
Zhao, X., Li, Y., Hua, T., Jiang, P., Yin, X., Yu, J., & Ding, B. (2017). Low-Resistance Dual-Purpose Air Filter Releasing Negative Ions and Effectively Capturing PM2.5. ACS Applied Materials & Interfaces, 9(13), 12054-12063. doi: http://dx.doi.org/10.1021/acsami.7b00351 (in English)
Zhou, P., Yang, Y., Huang, G., & Lai, A. C. K. (2018). Numerical and experimental study on airborne disinfection by negative ions in air duct flow. Building and Environment, 127, 204-210. doi: http://dx.doi.org/10.1016/j.buildenv.2017.11.006 (in English)
Sidorov, А. V. (2014). The technique of small air ions concentration measurement at the PC operator working place. Engineering industry and life safety, 1, 36-41. (in English)
Jurelionis, A., Gagytė, L., Prasauskas, T., Čiužas, D., Krugly, E., Šeduikytė, L., & Martuzevičius, D. (2015). The impact of the air distribution method in ventilated rooms on the aerosol particle dispersion and removal: The experimental approach. Energy and Buildings, 86, 305-313. doi: http://dx.doi.org/10.1016/j.enbuild.2014.10.014 (in English)
Downloads
Published
How to Cite
Issue
Section
License
Copyright and Licensing
This journal provides open access to all of its content.
As such, copyright for articles published in this journal is retained by the authors, under the terms of the Creative Commons Attribution 4.0 International License (CC BY 4.0). The CC BY license permits commercial and non-commercial reuse. Such access is associated with increased readership and increased citation of an author's work. For more information on this approach, see the Public Knowledge Project, the Directory of Open Access Journals, or the Budapest Open Access Initiative.
The CC BY 4.0 license allows users to copy, distribute and adapt the work in any way, provided that they properly point to the author. Therefore, the editorial board of the journal does not prevent from placing published materials in third-party repositories. In order to protect manuscripts from misappropriation by unscrupulous authors, reference should be made to the original version of the work.